CENTRIFUGE
CONSUL 22 R: HIGH CAPACITY, REFRIGERATED
Orto Alresa
TFT color touch screen, visible from more than 3 m.:
• Shows RPM and RCF, time, temperature, acceleration/deceleration values (PCBS) and unbalance location system (ULS).
• Speed programming in 10 RPM/10 xg steps.
• Real RCF values on screen based on accessories configuration.
• Count up/down from “0” or at “set RPM/RCF” for test reproducibility.
• Timer countdown/up from “0” or at “set RPM/ RCF” for reproducible tests.
• Timer from 1 sec. to 99 hours programmable in 1 sec. steps and hold position.
• PCBS: Progressive controlled acceleration and braking system up to 175 selectable ramps that prevents sample homogenization after separation.
• ULS: Unbalance location system indicating on the screen the number of the bucket which produces the unbalance switch off.
• Start delay: To program the time at which the cycle is to begin.
• Linked program: Permits the linking of up to 8 consecutive programmes without the need of user intervention
• 40 programmable memories, with protection under password.
• Several acoustic and visual messages showing the user the situation of the device.
Safety
Lid provided with security systems:
– Automatic lid lock system, motorized with double lock.
– Emergency lid-lock release.
– Locking and protection against opening along the run.
– Lid dropping protection.
– Port in the lid for calibration and operation checking.
Ergonomic design that allows close the lid effortless.
Unbalance detection and switch off.
Protection safety ring between the centrifugation chamber and the housing.
Chamber of centrifugation in stainless steel (easy cleaning).
Rotors can be removed with the lid closed.
Rotors and adapters autoclavable, easy to install by the user.
Automatic disconnection for energy saving up to 8 h.
Cooling
• Maintains the refrigeration after the centrifugation process.
• Precooling program with rotor spinning and temperature selectable.
• Guarantees 4 °C at maximum RPM.
• Temperature range from -20°C (-4°F) to 40°C (104°F) in 1°C/1°F steps. Programmable in °C o °F.
• Temperature sensor inside the chamber.
• Gas R 449A HFO (CFC free).
Directives
• EU Directives: 2011/65/EU, 2012/19/EU, 2014/30/EU, 2014/35/EU, 98/79/EC.
• Regulation n°: (EC) 1005/2009, (EU) 517/2014.
• Standards: EN 61010-1, EN 61010-2-101,EN 61010-2-020, EN 61326-2-6, EN 61326-1.
DIGTOR 22 : OIL/PETROL
Orto Alresa
With capacity for 4 tubes of 8”, 6”, trace and 28 “finger” tubes. Versatile and effective is the better option out of all the centrifuges for oil applications.
Designed for oil/petrol applications according the standards: ASTM D 91, D96, D 893, D 1796, D2273, D2709, D 2711, D 4007, D 5546, API 2542, API 2548, BS 4385, ISO 3734, ISO 9030, IP75, IP 359, NF M07-020, DIN 51793. Fits Babcock bottles
Tubes upright on rest. Gas Release System (GRS):
Gas release system (optional); pre-installation included.
TFT color touch screen, visible from more than 3 m.:
• Shows RPM and RCF, time, temperature, acceleration/deceleration values (PCBS and unbalance location system (ULS).
• Speed programming in 10 RPM/10 xg steps.
• Real RCF values on screen based on accessories configuration.
• Count up/down from “0” or at “set RPM/RCF” for test reproducibility.
• Timer countdown/up from “0” or at “set RPM/ RCF” for reproducible tests.
• Timer from 1 sec. to 99 hours programmable in 1 sec. steps and hold position.
• PCBS: Progressive controlled acceleration and braking system up to 175 selectable ramps that prevents sample homogenization after separation.
• ULS: Unbalance location system indicating on the screen the number of the bucket which produces the unbalance switch off.
• Start delay: To program the time at which the cycle is to begin.
• Linked program: Permits the linking of up to 8 consecutive programmes without the need of user intervention.
• 40 programmable memories, with protection under password.
• Several acoustic and visual messages showing the user the situation of the device.
Safety
Lid provided with security systems:
– Automatic lid lock system, motorized with double lock.
– Emergency lid-lock release.
– Locking and protection against opening along the run.
– Lid dropping protection.
– Port in the lid for calibration and operation checking.
Unbalance detection and switch off.
Protection safety ring between the centrifugation chamber and the housing.
Chamber of centrifugation in stainless steel (easy cleaning).
Rotors and adapters autoclavable, easy to install by the user.
Automatic disconnection for energy saving up to 8 h.
Heating
• Preheating program with rotor spinning and selectable temperature. It allows keeping the chamber at working temperature before starting the process.
• Regulation of the room temperature +5°C (41°F) to 80°C (176°F) in 1°C/1° F steps Programmable in °C o °F.
• Temperature sensor inside the chamber. Overheating protection.
• Internal isolated avoiding heat loss.
Directives
• EU Directives: 2011/65/EU, 2012/19/EU, 2014/30/EU, 2014/35/EU.
• Standards: EN 61010-1, EN 61010-2-101, EN 61010-2-020, EN 61326-2-6, EN 61326-1, EN 61010-2-010.
BIOCEN 22: MICROCENTRIFUGE
Orto Alresa
The Biocen 22 centrifuge is our offer for users requiring a microcentrifuge with possible applications for microhematocrit and microtubes. Its small size, good performance and great versatility make it an essential tool. It gives the user complete control from the beginning of the process and many values can be customised according to the processes. Built to ensure the minimum increase of temperature inside the chamber due to the high-speed centrifugation process.
We know how important a sample is as a part of a process and therefore we try to interfere as little as possible to avoid interference and ensure a precise, exact, reliable and rapid result.
LED screen:
• Shows RPM/ RCF and time.
• Speed programming in 50 RPM/ 10 xg steps.
• Timer countdown/up from “0” or at “set RPM/ RCF” for reproducible tests.
• Timer from 1 to 99 min. programmable in 1 min. steps and hold position.
• Acceleration and deceleration control in 3 steps: fast, soft and free.
• Acoustic and visual messages on screen showing the user the status of the equipment.
Safety
Lid provided with security systems:
– Automatic lid lock system, motorized.
– Emergency lid-lock release.
– Locking and protection against opening along the run.
– Lid dropping protection.
– Port in the lid for calibration and operation checking.
Ergonomic design that allows close the lid effortless. Unbalance detection and switch off.
Protection safety ring between the centrifugation chamber and the housing.
Chamber of centrifugation in stainless steel (easy cleaning).
Rotors can be removed with the lid closed. Hermetic lids.
Rotors and adapters autoclavable, easy to install by the user.
Forced ventilation to reduce temperature increasing
Automatic disconnection for energy saving, with deactivation option.
Directives
•EU Directives: 2011/65/EU, 2012/19/EU, 2014/30/EU, 2014/35/EU, 98/79/EC.
• Standards: EN 61010-1, EN 61010-2-101, EN 61010-2-020, EN 61326-2-6,EN 61326-1.